loading
MDVES200 Vacuum Eutectic Reflow Soldering Oven System 1
MDVES200 Vacuum Eutectic Reflow Soldering Oven System 2
MDVES200 Vacuum Eutectic Reflow Soldering Oven System 3
MDVES200 Vacuum Eutectic Reflow Soldering Oven System 4
MDVES200 Vacuum Eutectic Reflow Soldering Oven System 5
MDVES200 Vacuum Eutectic Reflow Soldering Oven System 6
MDVES200 Vacuum Eutectic Reflow Soldering Oven System 1
MDVES200 Vacuum Eutectic Reflow Soldering Oven System 2
MDVES200 Vacuum Eutectic Reflow Soldering Oven System 3
MDVES200 Vacuum Eutectic Reflow Soldering Oven System 4
MDVES200 Vacuum Eutectic Reflow Soldering Oven System 5
MDVES200 Vacuum Eutectic Reflow Soldering Oven System 6

MDVES200 Vacuum Eutectic Reflow Soldering Oven System

Application:

IGBT modules, TR components, MCM, hybrid circuit packages, discrete device packages, sensor/MEMS packages (water-cooled), high-power device packages, optoelectronic device packages, air-tight packages (water-cooled), eutectic bump welding, etc.

Product description:

The design basis of the MDVES200 vacuum sintering furnace is vacuum and water cooling control, which can not only ensure the void rate, but also increase the cooling rate.

The standard gas of MDVES200 includes: nitrogen, nitrogen-hydrogen mixed gas (95%/5%) and formic acid. The customer selects the corresponding gas as the process gas according to his actual situation, and does not need to worry about the additional configuration. The PLC control system of the equipment can well monitor the operations of vacuum pumping, inflation, heating control, and water cooling to ensure the stability of the customer's process.

MUX200 is a 10L cavity, the cost performance of the product is relatively high, which can meet the needs of research and production customers.

Features:

1. MDVES200 is a cost-effective product with a small footprint and complete functions, which can meet customer R&D and initial production use;

2. The standard configuration of formic acid, nitrogen and nitrogen-hydrogen gas can meet the gas demand of various products of customers, without the trouble of adding process gas pipeline for the follow-up;

3. Adopting water cooling control can increase the cooling rate, so that the production rate can be increased and the production can be maximized; 4. When the customer relates to the vacuum sealing of the tube shell, the water cooling design will highlight the advantages and avoid the air cooling caused by the tube sheet and The puncture problem of the tube shell;

Specification:

structure size

Basic frame

820*820*1000mm

cavity volume

10L

Maximum height of base

110mm

Observation window

include

Weight

220KG

Vacuum system

Vacuum pump

Vacuum pump with oil pollution filtering device

Vacuum level

Up to 5Pa

Vacuum configuration

1. Vacuum pump

2. Electric valve

Pumping speed control

The pumping speed of the vacuum pump can be set by

the host computer software

Pneumatic system

Process gas

N2, N2 / H2 (95% / 5%), HCOOH

First gas path

Nitrogen/nitrogen-hydrogen mixture (95%/5%)

Second gas path

HCOOH

Heating and cooling system

Heating method

Radiant heating, contact conduction, heating rate 150℃/min

Cooling method

Contact cooling, the maximum cooling rate is 120℃/min

Hot plate material

copper alloy, thermal conductivity:≥200W/m·℃

Heating size

240*210mm

Heating device

Heating device: the vacuum heating tube is used; the temperature is collected

by the Siemens PLC module, and the PID control is controlled

by the host computer Advantech.

Temperature range

Max 400℃

Power requirements

380V, 50/60HZ three-phase, maximum 40A

Control System

Siemens PLC + IPC

Equipment power

Coolant

Antifreeze or distilled water

≤20℃

Pressure:

0.2~0.4Mpa

coolant flow rate

>100L/min

Water tank water capacity

≥60L

Inlet water temperature

≤20℃

Air source

0.4MPa≤air pressure≤0.7MPa

Power supply

single-phase three-wire system 220V, 50Hz

Voltage fluctuation range

single phase 200~230V

Frequency fluctuation range

50HZ±1HZ

Equipment power consumption

about 5KW; grounding resistance≤4Ω;

Standard configuration:

Host system

including vacuum chamber,main frame, control hardware and software

Nitrogen pipeline

Nitrogen or nitrogen/hydrogen mixture can be used as process gas

Formic acid pipeline

Bringing formic acid into the process chamber via nitrogen

Water cooling pipeline

cooling the upper cover, lower cavity and heating plate

Water cooler

Provide continuous water cooling supply to equipment

Vacuum pump

Vacuum pump system with oil mist filtration

Operation Conditions

Temperature

10~35℃

Relative humidity

≤80%

The environment around the equipment is clean and tidy, the air is clean, and there should be

no dust or gas that can cause corrosion of electrical appliances and other metal surfaces or

cause conduction between metals.

    oops...!

    no product data.

    Go to homepage
    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs
    Related Products
    no data
    Copyright © 2024 Guangzhou Minder-Hightech Co.,ltd | Sitemap
    Customer service
    detect